Accuracy
- ± 0.13 % of Full Scale (Includes Non-Linearity, Hysteresis & Non-Repeatability)
Approvals & Certifications
Compensated Temperature
- -20° to 80° C (-4° to 176° F)
Electrical Connectors
- 2 Foot Multiconductor Cable
Humidity
- 10 to 90 % Relative Humidity, Non-Condensing
Media
- Compatible Gases
- Compatible Liquids
NACE & NIST
- NIST Traceable Calibration Certificate
Overpressure & Static Pressure Limits
- psi: 150 (kPa: 1,034, bar: 10.34) to psi: 1,000 (kPa: 6,895, bar: 68.9)
Pressure Range
- bar: 0 to 34.47
- kPa: 0 to 3,447
- psi: 0 to 500
Span & Zero Adjustments
- ± 0.5 mA, Non-Interactive
Temperature Effect
- Span: ± 1.5 % of Full Scale/38° C (100° F)
- Zero: 1.0 % of Full Scale/38° C (100° F)
Temperature Range
- -40° to 125° C (-40° to 260° F)