Series 655A 316 Wet/Wet Differential Pressure Transmitter

Brand: Dwyer Instruments, LLC

Series 655A Differential Pressure Transmitters are designed for high static/low DP applications designed especially for the End Users and OEM's where extreme overpressure and high performance of 0.25% accuracy and stability are required at ranges down to 3" w.c.

Every 655A Series is built using advanced manufacturing techniques to ensure symmetry between the HI and LO ports. Symmetry, along with automated welding procedures give these differential pressure transmitters excellent performance and reliability over time at high elevated line pressure.

Each unit includes a 6-point NIST certificate of calibration which demonstrates the unit's high level of performance.

The 655A Series transmitter pressure ports that are all welded 316 SS with an O-Ring free design making it ideal for high cyclical applications, capillary filled systems, or applications where a guaranteed leak free system is needed.
Features
  • Extreme overpressure and stability at low ranges provides durable device for OEM and end-user applications
  • High-accuracy device for low differential pressure designs requiring more precise measurements in support of application
  • NIST certificate available to demonstrate high-level of performance

Specifications

Accuracy

  • ± 0.25 % BFSL, RSS (Combined Effect of Non-Linearity, Hysteresis, & Repeatability)

Approvals & Certifications

  • CE

Compensated Temperature

  • -17.8° to 76.7° C (0° to 170° F)

Electrical Connectors

  • 6-Pin Connector
  • Cable Exit with 24” Cable

Enclosure, Body Material

  • 316 Stainless Steel

Environmental Protection

  • IP66
  • NEMA 4X

Loop Resistance

  • 1,500 ohms

Media

  • Gas
  • Liquids & Gases

NPT Connection

  • 1/4” NPT Female

Output

  • 4-20 mA

Power Requirement

  • 8-38 Vdc

Pressure Range

  • bar: 0 to 0.13
  • Inches WC: 0 to 200
  • kPa: 0 to 13.79
  • psid: 0 to 2

Pressure Type

  • Differential

Response Time

  • < 10 milliseconds

Sensor Orientation

  • Mount in Vertical Position: Zero Shifts up to ± 1” WC Depending on Orientation

Stability

  • ≤ ± 0.25 % of Full Scale Output/Year

Static Pressure

  • Span: ≤ ± 0.5 % psi: 1,000 (kPa: 6,895, bar: 68.9)
  • Zero: ≤ ± 0.25 % of Full Scale Output psi: 1,000 (kPa: 6,895, bar: 68.9)

Temperature Effect

  • ≤ ± 1.5 % of Full Scale Over Compensated Temperature Range

Temperature Range

  • -29° to 93° C (20° to 200° F)

Wetted Materials

  • 316, 316L Stainless Steel

  • Pump differential pressure
  • Critical process monitoring
  • High accuracy/low differential pressure OEM applications
show more