8030 In-Line Flowmeter
Brand: Burkert Fluid Control SystemsThe paddle wheel flowmeter for continuous flow measurement is especially designed for use in neutral, slightly aggressive, solid free liquids.
The flowmeter is made up of a compact fitting (S030) and an electronic module (SE30) quickly and easily connected together by a QuarterTurn. The Burkert designed fitting system ensures simple installation of the devices into all pipes from DN06 to DN65.
The flowmeter produces a frequency signal, proportional to the flow rate, which can easily be transmitted and processed by a Burkert transmitter/controller.
Features
- Economic integration in pipe systems without any additional piping
- 3-wire frequency pulse version to directly interface with PLC’s (both PNP and NPN)
- Connection to Burkert devices in remote versions
Specifications
Non-Weted Material
- Female Cable Plug: Body, Contact Holder and Cable Gland in PA
- Screw: Stainless Steel
- Plug Contact: Brass, PE
Wetted Material
- Axis: Ceramics (Al2O3)
- Seal: FKM or EPDM
Linearity
- ± 0.5 % of Full Scale
Repeatability
- ± 0.4 % of the Measured Valie
Measurement Deviation
- Standard K-factor: ± 2.5 % of Reading
- Teach-In: ± 1 % of the Measured Value
Viscosity
- 300 cSt, Max.
Operating Voltage
- 12-36 Vdc
Environmental Protection
- IP65
Voltage
- Dielectric Strengh: 2,300 Vac
Process Temperature
- PP: 0° to 80° C (32° to 176° F)
- PVC: 0° to 50° C (32° to 122° F)
- Stainless Steel, Brass, PVDF: -15° to 100° C (5° to 212° F)
Ambient Temperature
- Operating & Storage: -15° to 60° C (5° to 140° F)
Humidity
- ≤ 80 % RH, Non-Condensing
Pressure Range
- bar: 0 to 16
- kPa: 0 to 1,600
- psi: 0 to 232.16
Electrical Connectors
- 1.5 mm², Max.
- Cable Plug EN 175301-803
- Shielded Cable
Diameter
- Pipe: 1/4 to 2-1/2" (DN06 to DN 65)
Approvals & Certifications
- PED
- CE
Power Supply
- 12-36 Vdc
Measuring Range
- Flow Velocity: 0.3 to 10 m/sec
- Flow Rate: 0.5 to 1,000 l/min (0.13 to 265 gpm)