Deltabar FMD71/72 FMD72
Brand: Endress+HauserDeltabar FMD71/72 FMD72
Brand: Endress+Hauser
Extended Specs at a Glance
Process temperature:
–40...+125°C
(–40 ... +257°F)
(–40 ... +257°F)
Pressure measuring range:
400 mbar...10 bar
(6 psi...150 psi)
(6 psi...150 psi)
Measuring cell:
400 mbar...10 bar
(6 psi...150psi)
(6 psi...150psi)
Material process membrane:
316L, AlloyC,
Accuracy:
0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor
"PLATINUM" 0.05% of individual sensor
Process pressure / max. overpressure limit:
160 bar (2400 psi)
Main wetted parts:
316L, Alloy C
Field of application
Differential pressure electronical,
piezoresitive.
Membrane: metal, welded.
Level, volume- / mass measurement
in pressurized / vacuum systems.
Specifications
Brand
Industry
- Chemical
- Water, Wastewater & Waste
- Food & Beverage
- Power & Energy
- Mining, Minerals & Metals
- Oil & Gas
- Pulp & Paper (incl. Printing)
- Other industries
- Life Science
Product Family
- Deltabar
Continuous / Liquids
Characteristic / Application
- Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.
Supply / Communication
- 4...20 mA HART
Accuracy
- 0.075% of individual sensor,
- "PLATINUM" 0.05% of individual sensor
Long term stability
- 0.05% of URL/year of individual sensor
Ambient temperature
- –40...+80°C
- (–40... +176°F)
Process temperature
- –40...+125°C
- (–40 ... +257°F)
Process pressure / max. overpressure limit
- 160 bar (2400 psi)
Pressure measuring range
- 400 mbar...10 bar
- (6 psi...150 psi)
Main wetted parts
- 316L, Alloy C
Process connection
- Threads
- Flange (DIN, ASME,JIS)
Process connection hygienic
- DIN11851
- DIN11864-1
- Tri-Clamp
- DRD
- Varivent
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, FM, CSA, CSA C/US IEC Ex, NEPSI, INMETRO
Design approvals
- NACE MR0175
- EN10204-3.1
Hygienic approvals
- FDA
Options
- 4-line digital display
- SS- or Aluminium housing
Application limits
- Use the Software Applicator Sizing Electronic DP
Pressure
Characteristic
- Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.
Supply voltage
- 4...20 mA HART:
- 12...45V DC (Non Ex)
- Ex ia: 12...30V DC
Reference Accuracy
- 0.075% of individual sensor,
- "PLATINUM" 0.05% of individual sensor
Long term stability
- 0.05% of URL/year of individual sensor
Process temperature
- –40...+125°C
- (–40...+257°F)
Ambient temperature
- –40...+80°C
- (–40...+176°F)
Measuring cell
- 400 mbar...10 bar
- (6 psi...150psi)
Vacuum resistance
- 10 mbar (0.15 psi)
Max. overpressure limit
- 160 bar (2400 psi)
Process connection
- Threads
- Flange (DIN, ASME,JIS)
Process connection hygienic
- DIN11851
- DIN11864-1
- Tri-Clamp
- DRD
- Varivent
Material process membrane
- 316L, AlloyC,
Fill fluid
- Silicone oil
- Synthetic oil
Material housing
- Die-cast aluminum
- Stainless steel
Communication
- 4...20 mA HART
Certificates / Approvals
- ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex
Design approvals
- NACE MR0175,
- EN10204-3.1,
Hygienic approvals
- EHEDG
- 3A