8188 Guided Microwave Level Measurement Device

Brand: Burkert Fluid Control Systems

The Type 8188 is a level measurement device with cable, rod, both interchangeable probe or with coax probe, designed for continuous level measurement. The unit is suitable for liquids, for industrial use in all areas of process technology. 

With a measuring range up to 75 meters, the 8188 is best suited for tall vessels. Even process conditions such as strong steam generation, density fluctuations or changes of the dielectric constant do not influence the accuracy of the measurement. Build-up or condensation on the probe or vessel wall do not influence the measuring result. 

A liquid interface measurement is also possible with the Type 8188, typically an oil/ water interface.

Features

  • Universal level measurement device for liquids
  • Liquid interface measurement
  • Insensitive to dust and steam
  • 4-20 mA/HART - 2-Wires, ATEX/IECEx certification

Specifications

Non-Wetted Material

  • Cover: Polycarbonate (PC)
  • Housing: Plastic PBT (Polyester), PPS and Stainless Steel 316L (1.4404)
  • Grounding Terminal & Screw: Stainless Steel 316L
  • Seal Between housing and cover: EPDM
  • Cable Gland & Blind Plug: PA

Wetted Material

  • Seal: NBR with Aramid Fibres

Measuring Range

  • In Water: 0.08 to 75 m
  • In Oil: 0.10 to 77.85 m

Measuring Range Resolution

  • < 1 mm

Measurement Deviation

  • ± 2 mm

Display/Configuration Module

  • LCD in Full Dot Matrix

Non-Repeatability

  • ≤ ± 1 mm (max.)

Operating Voltage

  • Without Display/Configuration Module: 9.6-35 vDC, 9.6-30 Vdc (Ex ia Instrument)
  • With Display/Configuration Module: 16-35 VDC, 16-30 VDC (Ex ia instrument)

Output

  • 4-20 mA / HART

Process Connection

  • G 3/4", G 1"
  • 3/4" NPT, 1" NPT

Electional Connection

  • Cable Gland M20 x 1.5

Probe Length

  • 0.5 to 75 m

Ambient Temperature

  • -40° to 80° C (-40° to 176° F)

Humidity

  • 20% to 85 % RH, Non-Condensation

Pressure Range

  • bar: -1 to 40
  • kPa: -100 to 4,000
  • psi: -14.51 to 580.1

Process Temperature

  • -40° to 150° C (-40° to 302° F)

Environmental Protection

  • IP66
  • IP67

Approvals & Certifications

  • ATEX/IECEx
  • CE
  • EU
  • NAMUR: NE 21, NE 43, NE 53, NE 107
  • TÜV

Level measurement in:
  • Bio-ethanol storage tanks
  • Volatile and low-viscosity solvents vessels
  • Separating tank, to determine the exact proportion of each substance
show more