Series DPM Particulate Monitor

Brand: Dwyer Instruments, LLC

The DPM Particulate Monitor and PMS Particulate Sensor combine to provide a basic baghouse and cartridge filter leak detector designed for general maintenance planning and process protection.

It is easy to use and reliable. Leakage is gauged in real-time, on-the-spot, without prior baseline data and without signal tuning. 

Simply apply power and the general condition of the filter is quickly determined. An alarm point is set by simply moving an indicator up and down the gauge with the convenient, lockable key pad. For more precise alarm setup the large display provides both a logarithmic analog bar graph and an absolute digital readout. 

The log scale enables the user to observe both the baseline bleed through and the high peaks that are caused by filter cleaning cycles and developing leaks. Observation of both baseline and peaks is essential to setting proper alarms.

The digital readout in absolute units ensures correct interpretation of the readings and provides accurate historical comparisons.

The DPM Particulate Monitor is housed in a rugged cast aluminum enclosure. An LCD displays particulate levels in bar-graph and digital forms. A lockable membrane keypad is provided for setup and adjustment.
Features
  • Rugged Cast Aluminum Housing with Lockable Membrane Keypad
  • Programmable Alarm Points
  • Large LCD to Display Readouts Digitally

Specifications

Accuracy

  • ± 1 % of Range - Optional
  • ± 5 % of Range - Standard

Approvals & Certifications

  • CE
  • CSA

Consumption

  • 6 W, Max.

Display

  • LCD Display

Enclosure, Body Material

  • Cast Aluminum

Environmental Protection

  • Intrinsically Safe
  • IP66
  • NEMA 4X
  • Weatherproof

Isolation

  • 17 Vdc Loop Powered - DPM Control Unit Loop Power Supply

Output

  • 4-20 mA
  • 5 A at 240 V Res - 2 Form A (SPST) Rated Relays
  • 8 A, Max.

Power Requirement

  • 115 Vac at 50/60 Hz
  • 230 Vac 50/60 Hz
  • 24 Vdc

Resolution

  • 0.5 PA - Optional Display Resolution
  • 0.5 to 5,000 PA - Display Resolution
  • 5 PA - Standard Display Resolution

Temperature Range

  • -25° to 70° C (-13° to 160° F)

  • Baghouses
  • Cartridge Filters
  • Bin Vents
show more