Bandwidth
- DC to 3 MHz or DC to 10 MHz depending on input module
Basic Accuracy
- 0.2 %, 0.1 % or 0.03 % depending on input modules
Sampling Rate
- 0.33 MHz or 1 MHz depending on input modules
Direct Current Input Range
- 0.03 mA to 20 A depending on input module
Memory
- COnfigurations: 4MB
- Settings: 0.5MB
Working Temperature Range
- 5° C to 35° C
- 41° F to 95° F
Housing Material
- Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements.
Measuring Inputs
- Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket.
Frequency Range
- DC and 0.2 Hz to sample rate
Accuracy
- ± 0.01 % of measured value
Interface
- RS-232 interface for upload of firmware and data exchange with the PC.
- IEEE 488.2 / 1 MBit/s
- Ethernet / 10 MBit/s or 100 Mbit/s
Electrical Safety
- EN 61010-1 / 2nd Edition 1000 V CAT II (600 V CAT III)
- Degree of pollution 2, safety Class I
- EN 61558 for transformer
- EN 61010-2-031/032 for accessories
Maximum Inputs
- For voltage inputs Measurement range 1000 Veff, 2 kVpeak
- For current inputs Measurement range 10 Aeff, 20 Apeak
Electromagnetic Susceptibility
- Emission: IEC 61326-1, EN 50081-1, EN 55011 Class B
- Immunity: IEC 61326-1 / Annex A (industrial sector), EN 50082-1