Liquicap FTI51/52 FTI52

Brand: Endress+Hauser

Liquicap FTI51/52 FTI52

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Lean Lean

Specs at a Glance

Process temperature:
-80 °C ... +200 °C
(-112 °F ... +392 °F)
Process pressure / max. overpressure limit:
Vacuum ... 100 bar
(Vacuum ... 1450 psi)

Field of application

Liquicap FTI52 is a rope probe for point level detection of liquids that are highly viscous and tend to form build-up. Also used for detection of interface and foam of conductive liquids. Due to its active build-up compensation FTI52 offers maximum reliability and is suited for a wide range of applications thanks to international certificates. The parts in contact with the process are made of corrosion-resistant and FDA-listed materials - this guarantees a high safety standard.

For liquids that tend to form build-up. Interface detection of different liquids. Two-point control (pump control) with just one process connection. Foam detection of conductive liquids.

Process connections: Flanges, threads, special hygienic process connections

Temperature: -80 to +200°C (-112 to +392°F)

Pressure: Vacuum to +100bar (vacuum to +1,450psi)

Sensor length: 12m (39ft)

International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, marine approval

Features

  • Cost savings thanks to easy and fast commissioning as calibration takes place at the press of a button
  • Reliable and safe measurement due to active build-up compensation
  • Reliable and universal application thanks to wide range of certificates and approvals
  • Short reaction time
  • Material in contact with the process made of corrosion-resistant and FDA-listed materials
  • Two-stage overvoltage protection
  • No need for recalibration after replacing electronics

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Pulp & Paper (incl. Printing)

Product Family

  • Liquicap

Point Level / Liquids

Characteristic / Application

  • Capacitive Rope probe

Specialities

  • Interface detection
  • Foam detection

Ambient temperature

  • -50 °C ... +70 °C
  • (-58 °F ... +158 °F)
  • With separate housing:
  • -50 °C ... +120 °C
  • (-58°F ... +248 °F)

Process temperature

  • -80 °C ... +200 °C
  • (-112 °F ... +392 °F)

Process pressure / max. overpressure limit

  • Vacuum ... 100 bar
  • (Vacuum ... 1450 psi)

Main wetted parts

  • Insulation material: FEP, PFA
  • 316L

Process connection

  • G 3/4 ... 1 1/2
  • NPT 3/4 ... 1 1/2
  • Flange from DN25.../ASME 1".../JIS 10K...

Process connection hygienic

  • Tri-Clamp ISO2852 gap free plated
  • Dairy coupling
  • Flush mount

Sensor length

  • Total length of probe: max 12m (39 ft)

Communication

  • 2- wire 19-253 VAC
  • 3-wire
  • PFM
  • Relay DPDT
  • DC-PNP
  • 8/16 mA

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US, IEC Ex, TIIS, INMETRO, NEPSI, EAC

Safety approvals

  • Overfill prevention WHG
  • SIL

Design approvals

  • EN 10204-3.1
  • NACE MR0175

Marine approval

  • GL/ ABS/ DNV

Options

  • Inactive length
  • Active build-up compensation
  • Separate housing

Components

  • Transmitter
  • PFM: FTC325, FTC625, FTC470Z, FTC471Z
  • 3-wire:
  • FTC325

Application limits

  • Notice the pressure and temperature derating.
  • Notice for non conductive medium the DK.
show more