IXLdp Differential Pressure Transducer
Brand: Ashcroft Inc
Does not ship to OH, United States
The Ashcroft® IXLdp industrial differential transducer is used for measurement and control of extremely low pressures and flow.
Using patented Si-Glas™ technology, performance provides high sensitivity and repeatability for precise measurement and control at extremely low differential pressures.
An ideal choice when stable, reliable pressure measurement and TruAccuracy™ performance are needed.
Features- TruAccuracy™ performance ensures the IXLdp meets its rated accuracy out of the box and is ready for installation with no additional calibration adjustments required
- Rugged enclosure
- Wide selection of output signals and differential pressure ranges down to ±0.05 in. H2O
- Integral electrical termination isolates electronics from the process connections
- Optional FM approval for hazardous locations
- Outstanding overpressure protection
- Wide operating temperature capability
- Superior long-term stability
- 3-Year Warranty
- FM Approval optional
Specifications
Brand
Reference Temperature
- 70° F ±2° F (21° C ±1° C)
Accuracy
- ± 0.25 % of Span
- ± 0.5 % of Span
Stability
- ≤ ±0.25% Span/Year at reference conditions
Enclosure Rating
- NEMA 4X
Pressure Range
- Bidirectional: ±0.05 to ±100.00 in. H2O
- Unidirectional: 0.10 to 200.00 in. H2O
Response Time
- 250 ms
Process Connection
- 1/4" NPT Female
Housing Material
- 300 Series Stainless Steel
Output
- ± 2.5 Vdc (3-Wire), 12-36 Vdc
- ± 5 Vdc (3-Wire), 12-36 Vdc
- 0-5 Vdc (3-Wire), 12-36 Vdc
- 4-20 mA (2-Wire), 12-36 Vdc
- 1-5 Vdc (3-Wire), 12-36 Vdc
- 1-6 Vdc (3-Wire), 12-36 Vdc
Vibration Sweep
- < 0.2 % of Span/g Temporary Effect (10 to 130 Hz)
Operating Temperature
- -29° to 85° C (-20° to 185° F)
- FM: -4° to 104° F (-20° to 40° C)
Storage Temperature
- -40° to 99° C (-40° to 210° F)
Compensated Temperature
- -18° to 71° C (0° to 160° F)
Humidity
- 0 to 95 % RH Non-condensing
Static Pressure
- Maximum 100 psi
Proof Pressure
- psid: 20 (kPa: 137.9, bar: 1.37)
Burst Pressure
- psid: 50 (kPa: 344.7, bar: 3.44)
Electrical Connection
- 1/2" Female electrical conduit connections isolated from the electronics. Separate access cover for terminal connections
Wetted Material
- Aluminum, Titanium, PBT, Buna, Silicon, Glass, Gold, Silicone RTV & Stainless Steel
Thermal Coefficients
- For ± 0.25 % Accuracy: Zero/Span ± 0.01 % of Span/°F
- For ± 0.5 % Accuracy: Zero/Span ± 0.02 % of Span/°F
Warm-up Time
- < 1 second
Circuit Protection
- Reverse Wiring Protected
Supply Current
- 2.6 mA typical for Voltage output
Media
- Clean, Non-Corrosive & Dry Gases
Mounting Position Effect
- 0.1 inH₂O: ±0.8 % of Span/g
- 0.25 to 0.5 inH₂O: ±0.5 % of Span/g
- ≥ 1 inH₂O: ±0.1 % of Span/g
Approvals & Certifications
- FM
- HVAC/R
- Building Energy Management
- Comfort Control Systems
- Fume Hood Control
- Laboratory / Clean Room
- Hospital Room Pressurization
- Furnace / Stack Draft
- Pollution Monitoring
- Filter Monitoring
- Leak Detection
- Laminar Flow
- Medical Equipment
- Velocity Measurement
- Fan Tracking