IXLdp Differential Pressure Transducer

Brand: Ashcroft Inc
Does not ship to OH, United States

The Ashcroft® IXLdp industrial differential transducer is used for measurement and control of extremely low pressures and flow.

Using patented Si-Glas technology, performance provides high sensitivity and repeatability for precise measurement and control at extremely low differential pressures.

An ideal choice when stable, reliable pressure measurement and TruAccuracy performance are needed.

Features
  • TruAccuracy performance ensures the IXLdp meets its rated accuracy out of the box and is ready for installation with no additional calibration adjustments required
  • Rugged enclosure
  • Wide selection of output signals and differential pressure ranges down to ±0.05 in. H2O
  • Integral electrical termination isolates electronics from the process connections
  • Optional FM approval for hazardous locations
  • Outstanding overpressure protection
  • Wide operating temperature capability
  • Superior long-term stability
  • 3-Year Warranty
  • FM Approval optional

Specifications

Brand

Reference Temperature

  • 70° F ±2° F (21° C ±1° C)

Accuracy

  • ± 0.25 % of Span
  • ± 0.5 % of Span

Stability

  • ≤ ±0.25% Span/Year at reference conditions

Enclosure Rating

  • NEMA 4X

Pressure Range

  • Bidirectional: ±0.05 to ±100.00 in. H2O
  • Unidirectional: 0.10 to 200.00 in. H2O

Response Time

  • 250 ms

Process Connection

  • 1/4" NPT Female

Housing Material

  • 300 Series Stainless Steel

Output

  • ± 2.5 Vdc (3-Wire), 12-36 Vdc
  • ± 5 Vdc (3-Wire), 12-36 Vdc
  • 0-5 Vdc (3-Wire), 12-36 Vdc
  • 4-20 mA (2-Wire), 12-36 Vdc
  • 1-5 Vdc (3-Wire), 12-36 Vdc
  • 1-6 Vdc (3-Wire), 12-36 Vdc

Vibration Sweep

  • < 0.2 % of Span/g Temporary Effect (10 to 130 Hz)

Operating Temperature

  • -29° to 85° C (-20° to 185° F)
  • FM: -4° to 104° F (-20° to 40° C)

Storage Temperature

  • -40° to 99° C (-40° to 210° F)

Compensated Temperature

  • -18° to 71° C (0° to 160° F)

Humidity

  • 0 to 95 % RH Non-condensing

Static Pressure

  • Maximum 100 psi

Proof Pressure

  • psid: 20 (kPa: 137.9, bar: 1.37)

Burst Pressure

  • psid: 50 (kPa: 344.7, bar: 3.44)

Electrical Connection

  • 1/2" Female electrical conduit connections isolated from the electronics. Separate access cover for terminal connections

Wetted Material

  • Aluminum, Titanium, PBT, Buna, Silicon, Glass, Gold, Silicone RTV & Stainless Steel

Thermal Coefficients

  • For ± 0.25 % Accuracy: Zero/Span ± 0.01 % of Span/°F
  • For ± 0.5 % Accuracy: Zero/Span ± 0.02 % of Span/°F

Warm-up Time

  • < 1 second

Circuit Protection

  • Reverse Wiring Protected

Supply Current

  • 2.6 mA typical for Voltage output

Media

  • Clean, Non-Corrosive & Dry Gases

Mounting Position Effect

  • 0.1 inH₂O: ±0.8 % of Span/g
  • 0.25 to 0.5 inH₂O: ±0.5 % of Span/g
  • ≥ 1 inH₂O: ±0.1 % of Span/g

Approvals & Certifications

  • FM

  • HVAC/R
  • Building Energy Management
  • Comfort Control Systems
  • Fume Hood Control
  • Laboratory / Clean Room
  • Hospital Room Pressurization
  • Furnace / Stack Draft
  • Pollution Monitoring
  • Filter Monitoring
  • Leak Detection
  • Laminar Flow
  • Medical Equipment
  • Velocity Measurement
  • Fan Tracking
show more