(Pressure Ranges Related to 20° C) (bar Abs.)
- (1.64)
- (2.59)
- (3.97)
- (6.16)
- (8.87)
- (11.33)
Over Pressure Safety bar Abs.
Burst Pressure of Sensor bar Abs.
Process Connection
- G 1/2 B Male (Other Connections on Request)
Materials
- Synthetic oil
- Stainless Steel
Signal Output & Maximum Load RA
- 4 ... 20 mA, 2-Wire, RA ≤ (UB - 10 V) / 0.02 A with RA in Ohm and UB in Volt
Accuracy
- -40° C: 3 % of Span, 20° C: 1 % of Span, 60° C: 2.3 % of Span (Optimal accuracy point)
- -40° C: 4 % of Span, 20° C: 2 % of Span, 60° C: 3.3 % of Span (Beginning and end of Measuring Range)
1-Year Stability
- ≤ 0.3 % of Span (At reference Conditions)
Nominal Temperature
- -40° to +60° C (-40° to +140° F) [gas phase!]
Storage Temperature
- -40° to +80° C (-40° to +176° F)
EMC Directive
- 2004/108/EC, EN 61326 Emission (Group 1, Class B) and Immunity (Industrial locations)
High Voltage Strength
- DC 750 V (wiring versus Case)
Electromagnetic Immunity (EMI) / RFI Per IEC 61000-4
- IEC 61000-4-2 (ESD): test level 4 (8 kV)
- IEC 61000-4-3 (Field): test level 3 (10 V/m)
- IEC 61000-4-4 (Burst): test level X (± 2 kV)
- IEC 61000-4-5 (Surge): test level 2 (± 1 kV)
- IEC 61000-4-6 (Conducted RFI): test level 3 (10 V)
Electrical Connection
- Internal terminal Screws, cross section Max. 2.5 mm²
Wiring Protection
- Protected Against Reverse Polarity and Overvoltage
Ingress Protection
- IP67 per EN 60529 / IEC 529