AC Current via Jaw
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy: 2 % ± 5-digits
AC Current via Flexible Current Probe
- Range: 2500 A
- Resolution: 0.1 A (≤ 600 A), 1 A (≤ 2500 A)
- Accuracy: 3 % ± 5-digits
DC Current
- Range: 999.9 A
- Resolution: 0.1 A
- Accuracy: 2 % ± 5-digits
AC Voltage
- Range: 1000 V
- Resolution: 0.1 V (≤ 600.0 V), 1 V (≤ 1000 V)
- Accuracy: 1 % ± 5-digits
DC Voltage
- Range: 1000 V
- Resolution: 0.1 V (≤ 600.0 V), 1 V (≤ 1000 V)
- Accuracy: 1 % ± 5-digits
mV dc
- Range: 500.0 mV
- Resolution: 0.1 mV
- Accuracy: 1 % ± 5-digits
Frequency via Jaw
- Range: 5.0 Hz to 500.0 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.5 % ± 5-digits
Frequency via Flexible Current Probe
- Range: 5.0 Hz to 500.0 Hz
- Resolution: 0.1 Hz
- Accuracy: 0.5 % ± 5-digits
Resistance
- Range: 60 kΩ
- Resolution: 0.1 Ω (≤ 600 Ω), 1 Ω (≤ 6000 Ω), 10 Ω (≤ 60 kΩ)
- Accuracy: 1 % ± 5-digits
Capacitance
- Range: 1000 μF
- Resolution: 0.1 μF (≤ 100 μF), 1 μ F (≤ 1000 μF)
- Accuracy: 1 % ± 4-digits
Operating Humidity
- ≤ 90 % RH (at 10° C to 30° C)
- ≤ 75 % RH (at 30° C to 40° C)
- ≤ 45 % RH (at 40° C to 50° C)
Safety
- IEC 61010-1, Pollution Degree 2
- IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
- IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP Rating
- IEC 60529: IP30, non-operating