Thermometer Compact and cable probes TMR35

Brand: Endress+Hauser

Thermometer Compact and cable probes TMR35

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Fundamental Fundamental

Specs at a Glance

Operating temperature range:
PT 100:
-50 °C ...200 °C
(-58 °F ...392 °F)
Max. immersion length on request:
up to 600,00 mm (23,62'')
Accuracy:
class A acc. to IEC 60751
Response time:
t50 = 1 s
t90 = 2 s
Max. process pressure (static):
at 20 °C: 100 bar (1.450 psi)

Field of application

The Easytemp TMR35 is a compact thermometer that can be used to measure temperatures from -50 °C to +150 °C, or up to +200°C with neck, in hygienic applications. A variety of hygienic process connections leads to a high flexibility.

Features

  • Small, compact design made entirely of stainless steel
  • Extremely short response times
  • Highly accurate even with short insertion lengths

Specifications

Industry

  • Water, Wastewater & Waste
  • Food & Beverage
  • Power & Energy
  • Other industries
  • Life Science

Thermometer

Characteristic / Application

  • metric style
  • compact temperature probe
  • fast response time
  • hygienic design
  • hygienic process connection
  • with or without neck

Thermowell / protection tube

  • without (not intended to be used with thermowell)
  • to be used with thermowell
  • incl. Tee-/elbow thermowell

Insert / probe

  • pipe version, isolated wires, not flexible

Outer diameter protection tube / Insert

  • 3,0 mm (0,12'')
  • 6,0 mm (0,24'')

Max. immersion length on request

  • up to 600,00 mm (23,62'')

Material protection tube/ thermowell

  • 1.4404 (316L)

Process connection

  • hygienic:
  • conical sealing system G1/2" (metal)
  • clamp connections acc. to ISO 2852 / DIN 32676
  • screwed pipe joint acc. to DIN 11851
  • Varivent

Tip shape

  • straight

Surface roughness Ra

  • 0,4 μm (16 μin.)
  • 0,8 μm (32 μin.)

Operating temperature range

  • PT 100:
  • -50 °C ...200 °C
  • (-58 °F ...392 °F)

Max. process pressure (static)

  • at 20 °C: 100 bar (1.450 psi)

Accuracy

  • class A acc. to IEC 60751

Response time

  • t50 = 1 s
  • t90 = 2 s

Integration head transmitter

  • no (4…20mA Signal)

Certification

  • 3A
  • Marine approval
  • UL 3111-1
show more