GC51 Rangeable Indicating Pressure Transmitter
Brand: Ashcroft IncDoes not ship to OH, United States
The Ashcroft® GC51 rangeable pressure transmitter incorporates field-proven thin film technology for long term stability and reliability.
A 4 digit LCD along with an analog output provide both local and remote readings while a variety of electronic features are accessible through a display menu.
A perfect choice for wet or dry pressure measurement when a cost effective alternative to smart transmitters is desired.
Features- Compact, robust design
- ±25% of span accuracy for most ranges
- Pressure ranges: Gauge 50 to 7,500 psig, Compound ranges to -15 to 50 psig
- Min./max. feature records low and high pressure events
- Analog scaling
- “Loop check” allows easy display of user-defined units and verification without applying pressure
- Bright backlit 4-digit LCD display
- Easily rotatable display, 90° increments
- CRN and CE approved, RoHS compliant
Specifications
Brand
Reference Temperature
- 73° F (23° C)
Accuracy
- ± 0.25 % of Span (all ranges through 7,500 psi)
- ±1.0% of Span (20.00 ksi range) (includes effects of linearity, hysteresis & repeatability)
- ±0.5% of Span (9.00 and 15.00 ksi ranges)
Stability
- ±0.25% of Span (URL)/Year
Pressure Range
- Gauge: 5 to 20,000 psi (20.00 ksi)
- Compound: -3/3 psi to -14.7/50 psi
- Absolute: 20 psia
- Vacuum: -14.7
Process Connection
- 1/4" NPT Female (All ranges through 9,00 ksi)
- 9/16 -18 UNF-2B for 1/4" O.D. High Pressure Tubing (15.00 and 20.00 ksi ranges)
Media
- Fluids
- Gases
Supply Voltage
- 12-32 Vdc
Overpressure & Static Pressure Limits
- Overpressure: psi: 0 to 7,500 (kPa: 0 to 51,710, bar: 0 to 517.1)
Temperature Effect
- ± 0.02 % of Span (URL)/°C @ -10° to 60° C (14° to 140° F)
Shock & Vibration Resistance
- 10 g’s 16 ms, 5 g’s 150 Hz
Environmental Rating
- IP66/NEMA 4
Output Signal
- 4-20 mA, 2-Wire
Output Resolution
- 0.1 % of Span (URL)
Enclosure Material
- Aluminum, Epoxy Coated
Operating Temperature
- -10° to 60° C (14° to 140° F)
Storage Temperature
- -20° to 70° C (-4° to 158° F)
Compensated Temperature
- -10° to 60° C (14° to 140° F)
Insulation Resistance
- 50 Vdc (>100 MΩ)
Electrical Connection
- 1/2" NPT Female Conduit
- Cable Gland (Cable Diameters 0.35" to 0.47")
Display
- 4-Digit, 10 mm LCD with LED Backlight
- Accuracy: ± 0.25% of span (URL) + last digit
Approvals & Certifications
- CE
- EMC Directive 2004/108/EC
- IEC/EN 61326-1: 2006 (EMI Class A/EMS Table 2), EN 61326-2-3: 2006
Response Time
- 30 ms
- Municipal Water – Pumping, Tank Level Compressor Control
- Process Automation
- Hydraulic Systems