8025 Compact Flowmeter
Brand: Burkert Fluid Control SystemsThe flowmeter combines a paddle wheel flow sensor and an electronic module with a display in an IP65 enclosure. The electrical connection is provided via a cable plug or two cable glands (standard signal version).
The compact flowmeter is available in two versions:
- Standard signal (4-20 mA, frequency)
- Battery-powered indicator/totalizer
Features
- Up to PN 10, measurement tube size DN 06 to DN 400
- Display for showing the flow rate and volume with two totalisers, or dosing
- Automatic calibration via teach-in
- Inputs (with batch controller) and all outputs can be checked without the need for actual flow
- Overall total and daily total for batch quantity and number of batches, volume or mass totalisers displayed (with batch controller)
Specifications
Wetted Material
- Axis & Bearing: Ceramics (Al₂O₃)
- Sensor Armature & Paddle Wheel: PVDF
- Seal: FKM Standard (EPDM included, but not mounted)
Non-Wetted Material
- Housing, Cover, Lid & Union Nut: Polycarbonate (PC)
- Front Panel Film: Polyester
- Screw: Stainless Steel
- Seal: NBR
- Female Cable Plug/Male Fixed Plug: Body, contact holder and cable gland in PA; Cable gland seal and flat seal in NBR
- Cable Gland: PA
Display
- 15 x 60 mm, 8-Digit LCD, Alphanumeric, 15-Segments, 9 mm High
Pipe Diameter
- DN 20 to DN 400
Measuring Range
- Flow Velocity: 0.3 to 10 m/sec
- Flow Rate: 0.5 to 75,000 l/min
Linearity
- ± 0.5 % of Full Scale
Repeatability
- ± 0.4 % of the Measured Value
Operating Voltage
- 12-36 Vdc
- 4 x 1.5 Vdc AA Batteries
- 115/230 Vac
Medium Temperature
- PP: 0° to 80° C (32° to 176° F)
- PVC: 0° to 50° C (32° to 122° F)
- PVDF, Brass or Stainless Steel: -15° to 80° C (5° to 176° F)
Fluid Pressure
- Max. PN 10
Viscosity
- 300 cSt, Max.
Approvals & Certifications
- CE
- UL (C,US)
- PED
Electrical Connection
- Cable Plug or Cable Glands M20 × 1.5
Ambient Temperature
- -10° to 60° C (14° to 140° F)
Humidity
- ≤ 80 % RH, Non-Condensing
Environmental Protection
- IP65
Documentation
Data Sheets
Product Manuals
- Type 8025 8035 SE35 BATCH Batch controller operating instructions pdf 7.6 MB
- Type 8025 8035 SE35 Insertion or Inline flowmeter / transmitter operating instructions pdf 6.0 MB
- Type 8025 8035 SE35 Insertion/Inline flowmeter/Flow transm.,w. batteries operat. instr. pdf 2.1 MB
- Type 8025 Standard with and without relais assembly instructions pdf 404 KB