Specs at a Glance

Response time:
depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
Accuracy:
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
IEC/Class A
IEC/Class AA
Max. immersion length on request:
up to 30.000,00 mm (1181'')
Max. process pressure (static):
at 20 °C: 200 bar (2900 psi)
Operating temperature range:
Type K:
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 720 °C
(max. 1.328 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 WW; 6mm; 316L; -200...600oC
Pt100 TF; 3mm; 316L; -50…400oC
Pt100 TF; 6mm; 316L; -50…400oC
Pt100 StrongSens; 6mm; 316L; -50…500oC

Field of application

The iTHERM TMS02 MultiSens Flex can be customized for various applications: Bendable into a 3D layout, it provides a complete temperature profile using only a single process connection. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available with either TC/RTD technology or with our iTHERM StrongSens and features an advanced diagnostics chamber for additional safety.

Petrochemical industry

Heavy Chemical processes

Features

  • Infinite layouts of 3D sensors distribution for any desired process monitoring configuration
  • High degree of customization thanks to a modular product design for easy installation, process integration and maintenance
  • High degree of insert process compatibility as per standard IEC 60584, ASTM E230 and IEC 60751
  • On-board electronic heat protection for highest product durability
  • Compliance to different types of protection for use in hazardous locations for easy process integration
  • Diagnostic chamber as secondary process barrier for additional safety, capable of pressure monitoring for predictive maintenance through advanced diagnostics

Specifications

Industry

  • Chemical
  • Power & Energy
  • Oil & Gas
  • Other industries

Product Family

  • iTHERM MultiSens

Thermometer

Characteristic / Application

  • metric style
  • easy-to-use
  • suitable for hazardous areas
  • flanged process connection
  • light chemical processes
  • 3D sensors distributions
  • modular design
  • replaceable sensors during shutdown
  • diagnostic chamber

Thermowell / protection tube

  • without (for direct contact sensors type)
  • with (for replaceable sensors)
  • with (for increased mechanical protection)
  • Multi-thermowells, each one dedicated to a sensor

Insert / probe

  • mineral insulated (MI), flexible
  • mineral insulated (MI), flexible, with its own thermowell

Outer diameter protection tube / Insert

  • 6,0 mm (0,24'')
  • 8,0 mm (0,31")
  • 10,29 mm (1/8")

Max. immersion length on request

  • up to 30.000,00 mm (1181'')

Material protection tube/ thermowell

  • 1.4401 (316)
  • 1.4435 (316L)
  • 1.4541 (321)
  • 1.4550 (347)
  • Alloy 600 (2.4816)

Process connection

  • flange:
  • 2" ASME/ANSI B16.5 150
  • ...600
  • 3" ASME/ANSI B16.5 150
  • ..600
  • 4" ASME/ANSI B16.5 150
  • 6" ASME/ANSI B16.5 150
  • 8" ASME/ANSI B16.5 150
  • DN80 EN/DIN 1092.1 PN10
  • ...PN100
  • DN100 EN/DIN 1092.1 PN10
  • DN125 EN/DIN 1092.1 PN10
  • DN150 EN/DIN 1092.1 PN10
  • DN200 EN/DIN 1092.1 PN10

Tip shape

  • straight
  • reinforced
  • easy-fix

Operating temperature range

  • Type K:
  • max. 1.150 °C
  • (max. 2.102 °F)
  • Type J:
  • max. 720 °C
  • (max. 1.328 °F)
  • Type N:
  • max. 1.100 °C
  • (max. 2.012 °F)
  • Pt100 WW; 3mm; 316L; -200...600oC
  • Pt100 WW; 6mm; 316L; -200...600oC
  • Pt100 TF; 3mm; 316L; -50…400oC
  • Pt100 TF; 6mm; 316L; -50…400oC
  • Pt100 StrongSens; 6mm; 316L; -50…500oC

Max. process pressure (static)

  • at 20 °C: 200 bar (2900 psi)

Accuracy

  • class 2 acc. to IEC 60584
  • ASTM E230 and ANSI MC 96.1
  • IEC/Class A
  • IEC/Class AA

Response time

  • depending on configuration:
  • TC:
  • t50 = 2 s
  • t90 = 5 s
  • RTD:
  • t50 = 0,8s
  • t90 = 2s

Integration head transmitter

  • yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

Ex - approvals

  • ATEX
  • IECEx
  • UL
  • FM
  • CSA
  • NEPSI
  • CCC Ex ia

Certification

  • SIL (transmitter only)
show more