Condumax CLS13

Brand: Endress+Hauser

Condumax CLS13

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Specs at a Glance

Process pressure:
max. 40 bar (580 psi)
Process temperature:
max. 250 °C (482 °F)
Measuring range:
k=0,01: 0-20,0 µS/cm
k=0,1: 0-200,0 µS/cm

Field of application

Condumax CLS13 is a robust conductivity sensor for steam/water cycles in power plants. It is optimized for low conductivities (even under very high temperatures and pressures) to protect your processes from deposits and corrosion. Low maintenance and simple to commission (large connection compartment), this is the ideal sensor for tough environments.

Condumax CLS13 measures conductivity in the steam/water cycle in the power & energy industry:

  • Condensate monitoring
  • Boiler feedwater monitoring
  • Boiler blowdown control
  • The sensor can be used in all low conductivity applications with very high temperatures and pressures.
  • With its international explosion protection approvals, such as ATEX and FM, the sensor is suitable for hazardous area use.

Features

  • Reliable and accurate measuring values at low conductivities
  • Optimized for high pressures and temperatures up to 250°C (482°F)
  • Easy cleaning thanks to stainless steel body and removable outer electrode
  • Robust design for high durability
  • Quality certificate stating the individual cell constant

Specifications

Industry

  • Chemical
  • Power & Energy
  • Mining, Minerals & Metals
  • Other industries

Product Family

  • Condumax

Conductivity

Application

  • Process, power plant

Characteristic

  • 2-electrode conductivity cell for high temperature applications.

Measuring range

  • k=0,01: 0-20,0 µS/cm
  • k=0,1: 0-200,0 µS/cm

Measuring principle

  • Coaxially arranged electrodes for high temperature applications

Design

  • 2-electrode conductivity cell with coaxially arranged electrodes
  • Connection head and cooling body made of casting aluminium with fixed cable connection PG16

Material

  • Electrode: 1.4571
  • Sealing: Kalrez, ceramic

Dimension

  • Electrode diameter: 25 mm (0.984 inch)
  • Immersion depth: 50 to 115 mm (1.97 to 4.48 inch)
  • Weight: 3kg

Process temperature

  • max. 250 °C (482 °F)

Process pressure

  • max. 40 bar (580 psi)

Temperature sensor

  • Integrated Pt100

Ex certification

  • ATEX

Connection

  • Process connection: G1"

Ingress protection

  • IP67

Additional certifications

  • Calibration certificate with cellconstant

Documentation

BA (Operating instruction)

TI (Technical information)

show more