Accuracy Class
- 2.5: Scale Ranges from 0 ... 40 mbar to 0 ... 600 mbar
- 4.0: Scale Ranges 0 ... 16 mbar and 0 ... 25 mbar
Scale Ranges
- 0 to 16 mbar to 0 to 600 mbar
Pressure Limitation
- Fluctuating: Full Scale Value
- Steady: Full Scale Value
Maximum Working Pressure (Static Pressure)
Permissible Temperature
- Medium: +70° C Max.
- Ambient: -15° to +60° C
Temperature Effect
- When the temperature of the measuring system deviates from the reference temperature (+20° C): Max. ± 0.5 %/10 K of true scale value
Process Connections (Wetted)
- Lower Mount or Back Mount, 2 x G 1/8 Female
Case (Wetted)
- Aluminium, Black, Pressure-tight
Pressure Element (Wetted)
Separating Diaphragm of Measuring Chamber (Wetted)
- Diaphragm, Silicone Rubber
Movement (Wetted)
- Copper Alloy, wear parts argentan
Dial (Wetted)
- Aluminium, White, Black Lettering
Installation
- According to affixed symbols, ⊕ High Pressure,
- ⊖ Low Pressure