Type S056 Magnetic Inductive Sensor with Hygienic Process Connection

Brand: Burkert Fluid Control Systems

The type S056 magnetic inductive flow sensor (compact or separated version) is recommended for applications with low flow rate and liquids with a minimal conductivity. 

When combined with the SE58 M or SE58 L transmitters (minimum required conductivity: 5 µS/cm) it builds a flow measurement device with different performance, functions, materials and approvals with an appropriate suitability for the respective application depending on the individual requirements. 

With the SE58 M and SE58 L compact devices or remote versions are created for which the transmitter and sensor are connected by 2 cables up to a maximum length. Standard process connections available for the S056 are clamp or thread (dairy thread) connections.

When connected to an actuator such as a valve, the S056 sensor in combination with the SE58 L transmitter can also be used to control high-precision filling operations.

Features

  • For connection to a type SE58 transmitter (with display, in compact or remote version) for flow measurement
  • Hygienic variant, 3A certification variant, 3A certification
  • For food, beverage or pharmaceutical applications
  • Flow measurement 0.2... approx. 4,500 l/min for DN 03... DN 100

Specifications

Wetted Material

  • Electrode & Clamp: Stainless Steel 316L
  • Lining: PTFE (conform to FDA)
  • Seal: FKM (conform to FDA), EPDM (on request, conform to FDA)

Sensor Housing Material

  • Stainless Steel 304/1.4301

Junction Box

  • Only for Remote Sensor: Stainless Steel 304 (1.4301) Polished

Pipe Diameter

  • DN 03 to DN 100

Measuring Range

  • 0-10 l/h to 0-280 m3/h

Measurement Deviation

  • In Compact or Remote L Variant: ≤ ± 0.2 % of the Measured Value for Flow Velocity > 0.5 m/s
  • In Compact or Remote M Variant: ≤ ± 0.8 % of the Measured Value for Flow Velocity > 0.5 m/s
  • In Compact S Variant: ≤ ± 0.5 % of the Measured Value for Flow Velocity > 0.5 m/s

Repeatability

  • In Compact or Remote L Variant: ≤ ± 0.1 % of the Measured Value for Flow Velocity > 0.5 m/s
  • In Compact or Remote M Variant: ≤ ± 0.4 % of the Measured Value for Flow Velocity > 0.5 m/s
  • In Compact S Variant: ≤ ± 0.25 % of the Measured Value for Flow Velocity > 0.5 m/s

Velocity Range

  • 0.4 to 10 m/s

Certification & Approval

  • CE
  • 3A
  • FDA
  • EC 1935/2004 declaration

Fluid Temperature

  • -20° to 130° C (-4° to 2660° F)

Ambient Temperature

  • -20° to 60° C (-4° to 140° F)

Pipe Connection

  • DIN 11851, clamp ISO 2852 or clamp BS 4825 (SMS 1146 (from DN 10) on request)

Electrical Connection

  • 2 Cable Glands PG9 (for remote variant of the sensor)

Relative Air Humidity

  • ≤ 90 %, Without Condensation
show more