Temperature Engineered Solution TMS02
Brand: Endress+HauserTemperature Engineered Solution TMS02
Brand: Endress+Hauser
Xpert Specs at a Glance
Response time:
depending on configuration:
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
TC:
t50 = 2 s
t90 = 5 s
RTD:
t50 = 0,8s
t90 = 2s
Accuracy:
class 2 acc. to IEC 60584
ASTM E230 and ANSI MC 96.1
IEC/Class A
IEC/Class AA
ASTM E230 and ANSI MC 96.1
IEC/Class A
IEC/Class AA
Max. immersion length on request:
up to 30.000,00 mm (1181'')
Max. process pressure (static):
at 20 °C: 200 bar (2900 psi)
Operating temperature range:
Type K:
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 720 °C
(max. 1.328 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 WW; 6mm; 316L; -200...600oC
Pt100 TF; 3mm; 316L; -50…400oC
Pt100 TF; 6mm; 316L; -50…400oC
Pt100 StrongSens; 6mm; 316L; -50…500oC
max. 1.150 °C
(max. 2.102 °F)
Type J:
max. 720 °C
(max. 1.328 °F)
Type N:
max. 1.100 °C
(max. 2.012 °F)
Pt100 WW; 3mm; 316L; -200...600oC
Pt100 WW; 6mm; 316L; -200...600oC
Pt100 TF; 3mm; 316L; -50…400oC
Pt100 TF; 6mm; 316L; -50…400oC
Pt100 StrongSens; 6mm; 316L; -50…500oC
Field of application
The iTHERM TMS02 MultiSens Flex can be customized for various applications: Bendable into a 3D layout, it provides a complete temperature profile using only a single process connection. The device is configurable with or without thermowells for optimal response times, mechanical strength or sensors replaceability. It is available with either TC/RTD technology or with our iTHERM StrongSens and features an advanced diagnostics chamber for additional safety.
Petrochemical industry
Heavy Chemical processes
Features
- Infinite layouts of 3D sensors distribution for any desired process monitoring configuration
- High degree of customization thanks to a modular product design for easy installation, process integration and maintenance
- High degree of insert process compatibility as per standard IEC 60584, ASTM E230 and IEC 60751
- On-board electronic heat protection for highest product durability
- Compliance to different types of protection for use in hazardous locations for easy process integration
- Diagnostic chamber as secondary process barrier for additional safety, capable of pressure monitoring for predictive maintenance through advanced diagnostics
Specifications
Brand
Industry
- Chemical
- Power & Energy
- Oil & Gas
- Other industries
Product Family
- iTHERM MultiSens
Thermometer
Characteristic / Application
- metric style
- easy-to-use
- suitable for hazardous areas
- flanged process connection
- light chemical processes
- 3D sensors distributions
- modular design
- replaceable sensors during shutdown
- diagnostic chamber
Thermowell / protection tube
- without (for direct contact sensors type)
- with (for replaceable sensors)
- with (for increased mechanical protection)
- Multi-thermowells, each one dedicated to a sensor
Insert / probe
- mineral insulated (MI), flexible
- mineral insulated (MI), flexible, with its own thermowell
Outer diameter protection tube / Insert
- 6,0 mm (0,24'')
- 8,0 mm (0,31")
- 10,29 mm (1/8")
Max. immersion length on request
- up to 30.000,00 mm (1181'')
Material protection tube/ thermowell
- 1.4401 (316)
- 1.4435 (316L)
- 1.4541 (321)
- 1.4550 (347)
- Alloy 600 (2.4816)
Process connection
- flange:
- 2" ASME/ANSI B16.5 150
- ...600
- 3" ASME/ANSI B16.5 150
- ..600
- 4" ASME/ANSI B16.5 150
- 6" ASME/ANSI B16.5 150
- 8" ASME/ANSI B16.5 150
- DN80 EN/DIN 1092.1 PN10
- ...PN100
- DN100 EN/DIN 1092.1 PN10
- DN125 EN/DIN 1092.1 PN10
- DN150 EN/DIN 1092.1 PN10
- DN200 EN/DIN 1092.1 PN10
Tip shape
- straight
- reinforced
- easy-fix
Operating temperature range
- Type K:
- max. 1.150 °C
- (max. 2.102 °F)
- Type J:
- max. 720 °C
- (max. 1.328 °F)
- Type N:
- max. 1.100 °C
- (max. 2.012 °F)
- Pt100 WW; 3mm; 316L; -200...600oC
- Pt100 WW; 6mm; 316L; -200...600oC
- Pt100 TF; 3mm; 316L; -50…400oC
- Pt100 TF; 6mm; 316L; -50…400oC
- Pt100 StrongSens; 6mm; 316L; -50…500oC
Max. process pressure (static)
- at 20 °C: 200 bar (2900 psi)
Accuracy
- class 2 acc. to IEC 60584
- ASTM E230 and ANSI MC 96.1
- IEC/Class A
- IEC/Class AA
Response time
- depending on configuration:
- TC:
- t50 = 2 s
- t90 = 5 s
- RTD:
- t50 = 0,8s
- t90 = 2s
Integration head transmitter
- yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
- ATEX
- IECEx
- UL
- FM
- CSA
- NEPSI
- CCC Ex ia
Certification
- SIL (transmitter only)