8098 FLOWave SAW-Flowmeter
Brand: Burkert Fluid Control SystemsSpecifications
Process Connection Material
- 316L Stainless Steel / 1.4435
Housing Material
- Transmitter & Sensor: Stainless Steel 304/1.4301
- Sensor: Stainless Steel 316L/1.4435
Cover Material
- Stainless Steel 304/1.4301
Seal Material
- VMQ Silicone
Cable Material
- Body in Nickel Plated Brass & seal in TPE (thermoplastic elastomer)
Approvals & Certifications
- 3-A Sanitary
- EHEDG
- FAD
- CE
- NAMUR NE107
- UL (C,US)
- ATEX/IECEx/NEPSI
- PED 2014/68/EU
- CRN
- Test Report 2.2 for Surface Finish
- Inspection Certificate 3.1
Electrical Protection
- Reversed Polarity of DC
Measuring Range
- Volume Flow Rate: 0-1.7 m³/h Up to 0-200 m³/h
- Temperature: -20° to 140° C (-4° to 284° F)
- Flow Velocity: 0 to 10 (Full Scale) m/s
- Density: 0.8 to 1.3 g/cm3
- Mass Flow Rate: 0-1,360 kg/h Up to 0-260,000 kg/h
Environmental Protection
- IP65
- IP67
- NEMA 4X
Operating Voltages
- 12-35 Vdc Filtered & Regulated, Limited Energy Source
Electrical Connection
- 2 Cable Glands M20 x 1.5
- 1 × 5-pin M12 male connector
Display
- 2.4", 240 x 160 Pixel Monochrome Graphic
- Languages: German, English, French
Resolution
- 4-20 mA Output: 0.8 µA
Operating Voltage
- 12-35 VDC, Filtered & Regulated
Ambient Temperature
- -10° to 70° C (14° to 158° F)
Storage Temperature
- -20° to 70° C (-4° to 158° F)
Relative Air Humidity
- < 85 %, without Condensation
Fluid Temperature
- Fluid: -20° to 110° C (-4° to 230° F)
- Hygienic Applications