Accuracy
- ≤ ± 0.25 % of Span - Including Non-Linearity, Hysteresis, Zero Offset & End Value Deviation (Corresponds to Measured Error Per IEC 61298-2)
- ≤ ± 0.5 % of Span
Ambient Temperature Range
- -30° to 105° C (-22° to 221° F)
Applications
- Brackish Water & Fuel Tanks in Shipbuilding
- Mining & Gas Extraction
- Oil & Fuel Storage Tanks
- Wastewater Treatment & Biogas Production
Approvals & Certifications
- ATEX - Ex I, Zone 1 Gas, [II 2 G Ex ia IIC T4/T5/T6 Gb]
- ATEX - Mining, [I M1 Ex ia I Ma]
- ATEX - Zone 0 Gas, [II 1 G Ex ia IIA T4/T5/T6 Ga]
- ATEX - Zone 1 Mounting to Zone 0 Gas, [II 1/2 G Ex ia IIC T4/T5/T6 Ga/Gb]
- ATEX - Zone 20 Dust, [II 1D Ex ia IIIC T120° C Da]
- BelCT
- CE
- CRN - Safety (e.g. Electr. Safety, Overpressure, to), Canada
- CSA - Canadian Zone Designation: Class I, Zone 0, Ex ia, IIC, IP65, DIP A20
- CSA - Hazardous Areas, Class I, Div. 1, Groups A, B, C, D. Class II, Groups E, F, G, Class III.
- CSA - Safety (e.g. Electr. Safety, Overpressure, to)
- CSA - US Zone Designation: Class I, Zone 0, AEx ia, IIC, IP65
- EAC - Hazardous Areas, Ex I, Zone 1 Gas, [1ExiaIICT4/T5/T6 X]
- EAC - Mining, [POExiaI X]
- EAC - Zone 0 Gas, [0ExiaIIAT4/T5/T6 X]
- EAC - Zone 1 Mounting to Zone 0 Gas, [1ExiaIICT4/T5/T6 X]
- EAC - Zone 20 Dust, [Ex iaD 20 T80° C X]
- EMC
- EN 61326 Emission (Group 1, Class B) & Interference Immunity (Industrial Application)
- Ex
- FM - Class I, Zone 0, AEx ia IIC
- FM - Dust Ignition-proof for Class II, III, Div. 2, Groups F, G
- FM - Hazardous Areas, Intrinsically Safe Class I, II & III, Div. 1, Grade A, B, C, D, E, F, G
- GL - Ships, Shipbuilding (e.g. Offshore)
- GOST
- IECEx - Hazardous Areas, Ex I, Zone 1 Gas, [Ex ia IIC T4/T5/T6 Gb]
- IECEx - Mining, [Ex ia I Ma]
- IECEx - Zone 0 Gas, [Ex ia IIA T4/T5/T6 Ga]
- IECEx - Zone 1 Mounting to Zone 0 Gas, [Ex ia IIC T4/T5/T6 Ga/Gb]
- IECEx - Zone 20 Dust, [Ex ia IIIC T120° C Da]
- INMETRO - Hazardous Areas, Ex I, Zone 1 Gas, [Ex ia IIC T4/T5/T6 Gb]
- INMETRO - Metrology, Measurement Technology
- INMETRO - Mining, [Ex ia I Ma]
- INMETRO - Zone 0 Gas, [Ex ia IIA T4/T5/T6 Ga]
- INMETRO - Zone 1 Mounting to Zone 0 Gas, [Ex ia IIC T4/T5/T6 Ga/Gb]
- INMETRO - Zone 20 Dust, [EX Ia IIIC T120° C Da]
- KazlnMetr
- UkrSEPRO
- UZSTANDARD
BSP Connection
- G 1/2” B Male
- G 1/4” Female Thread (Only in Hastelloy)
Enclosure, Body Material
- 316L Stainless Steel
- Hastelloy
Overpressure & Static Pressure Limits
- psi: 55 to 360 (kPa: 380 to 2.480, bar: 3.8 to 24.8)
Pressure Range
- bar: 0 to 25
- Inches WC: 0 to 250
- kPa: 0 to 2,500
- psi: 0 to 300
Repeatability
- Non-Repeatability: ≤ ± 0.1 % of Span
Storage Temperature
- -10° to 60° C (14° to 140° F)
Temperature Range
- -30° to 105° C (-22° to 221° F)
Wetted Materials
- 316L Stainless Steel
- FEP
- Hastelloy
- Polyurethane