8081 Flowmeter for Water Continuous Measurement

Brand: Burkert Fluid Control Systems

The Type 8081 ultrasonic flowmeter is intended for the measurement of water flows which may be slightly charged with contaminants. 

It consists of an electronic module and a brass fitting with a built-in measuring tube. It enables a control loop to be established. 

The electrical connection is made via an 5-pin M12 fixed connector.

Features

  • Ultrasonic flowmeter using transit time method
  • Dynamic range ≥ 1:250
  • Low pressure drop
  • No flow-settling section necessary in the inlet and/or outlet

Specifications

Non-Wetted Material

  • Housing: PPS
  • Cover: PA
  • Screw: Stainless Steel
  • Fixed Connector: Silicone

Wetted Material

  • Fitting Body: Brass
  • Measuring Tube: PES
  • Seal: EPDM

Pipe Diameter

  • DN 15 to DN 25

Relative Air Humidity

  • ≤ 80%, Non-Condensing

Measuring Range

  • 0.06 to 200 L/minute

Environmental Protection

  • IP65

Pipe Connection

  • G or NPT External Thread; 3/4", 1" or 1-1/4"¼

Power Supply

  • 12-36 Vdc

Current Consumption

  • Consumption with Load: < 1 A
  • Own Consumption: < 4 mA

Fluid Temperature

  • 5° to 90° C (41° to 194° F)

Fluid Pressure

  • PN 16 (232.16 PSI)

Approvals & Certifications

  • PED 97/23/CE
  • CE

Operating & Storage Temperature

  • 5° to 55° C (41° to 131° F)

Repeatability

  • ≤ 1 %

Electrical Connection

  • 5-Pin M12 Male Fixed Connector for 5-Pin M12 female connector