IXLdp Differential Pressure Transducer

Brand: Ashcroft Inc
Does not ship to OH, United States

The Ashcroft® IXLdp industrial differential transducer is used for measurement and control of extremely low pressures and flow.

Using patented Si-Glas™ technology, performance provides high sensitivity and repeatability for precise measurement and control at extremely low differential pressures.

An ideal choice when stable, reliable pressure measurement and TruAccuracy™ performance are needed.

Features

  • TruAccuracy™ performance ensures the IXLdp meets its rated accuracy out of the box and is ready for installation with no additional calibration adjustments required
  • Rugged enclosure
  • Wide selection of output signals and differential pressure ranges down to ±0.05 in. H2O
  • Integral electrical termination isolates electronics from the process connections
  • Optional FM approval for hazardous locations
  • Outstanding overpressure protection
  • Wide operating temperature capability
  • Superior long-term stability
  • 3-Year Warranty
  • FM Approval optional

Specifications

Brand

Reference Temperature

  • 70° F ±2° F (21° C ±1° C)

Accuracy

  • ± 0.25 % of Span
  • ± 0.5 % of Span

Stability

  • ≤ ±0.25% Span/Year at reference conditions

Enclosure Rating

  • NEMA 4X

Pressure Range

  • Bidirectional: ±0.05 to ±100.00 in. H2O
  • Unidirectional: 0.10 to 200.00 in. H2O

Response Time

  • 250 ms

Process Connection

  • 1/4" NPT Female

Housing Material

  • 300 Series Stainless Steel

Output

  • ± 2.5 Vdc (3-Wire), 12-36 Vdc
  • ± 5 Vdc (3-Wire), 12-36 Vdc
  • 0-5 Vdc (3-Wire), 12-36 Vdc
  • 4-20 mA (2-Wire), 12-36 Vdc
  • 1-5 Vdc (3-Wire), 12-36 Vdc
  • 1-6 Vdc (3-Wire), 12-36 Vdc

Vibration Sweep

  • < 0.2 % of Span/g Temporary Effect (10 to 130 Hz)

Operating Temperature

  • -29° to 85° C (-20° to 185° F)
  • FM: -4° to 104° F (-20° to 40° C)

Storage Temperature

  • -40° to 99° C (-40° to 210° F)

Compensated Temperature

  • -18° to 71° C (0° to 160° F)

Humidity

  • 0 to 95 % RH Non-condensing

Static Pressure

  • Maximum 100 psi

Proof Pressure

  • psid: 20 (kPa: 137.9, bar: 1.37)

Burst Pressure

  • psid: 50 (kPa: 344.7, bar: 3.44)

Electrical Connection

  • 1/2" Female electrical conduit connections isolated from the electronics. Separate access cover for terminal connections

Wetted Material

  • Aluminum, Titanium, PBT, Buna, Silicon, Glass, Gold, Silicone RTV & Stainless Steel

Thermal Coefficients

  • For ± 0.25 % Accuracy: Zero/Span ± 0.01 % of Span/°F
  • For ± 0.5 % Accuracy: Zero/Span ± 0.02 % of Span/°F

Warm-up Time

  • < 1 second

Circuit Protection

  • Reverse Wiring Protected

Supply Current

  • 2.6 mA typical for Voltage output

Media

  • Clean, Non-Corrosive & Dry Gases

Mounting Position Effect

  • 0.1 inH₂O: ±0.8 % of Span/g
  • 0.25 to 0.5 inH₂O: ±0.5 % of Span/g
  • ≥ 1 inH₂O: ±0.1 % of Span/g

Approvals & Certifications

  • FM

  • HVAC/R
  • Building Energy Management
  • Comfort Control Systems
  • Fume Hood Control
  • Laboratory / Clean Room
  • Hospital Room Pressurization
  • Furnace / Stack Draft
  • Pollution Monitoring
  • Filter Monitoring
  • Leak Detection
  • Laminar Flow
  • Medical Equipment
  • Velocity Measurement
  • Fan Tracking
show more