Deltabar FMD71/72 FMD72

Brand: Endress+Hauser

Deltabar FMD71/72 FMD72

Brand: Endress+Hauser

Rust Automation & Controls, Endress+Hauser's exclusive USA representative in:
 CA CO HI MT   Parts of ID ND NV   UT WY

Extended Extended

Specs at a Glance

Process temperature:
–40...+125°C
(–40 ... +257°F)
Pressure measuring range:
400 mbar...10 bar
(6 psi...150 psi)
Measuring cell:
400 mbar...10 bar
(6 psi...150psi)
Material process membrane:
316L, AlloyC,
Accuracy:
0.075% of individual sensor,
"PLATINUM" 0.05% of individual sensor
Process pressure / max. overpressure limit:
160 bar (2400 psi)
Main wetted parts:
316L, Alloy C

Field of application

Differential pressure electronical,
piezoresitive.
Membrane: metal, welded.
Level, volume- / mass measurement
in pressurized / vacuum systems.

Specifications

Industry

  • Chemical
  • Water, Wastewater & Waste
  • Food & Beverage
  • Power & Energy
  • Mining, Minerals & Metals
  • Oil & Gas
  • Pulp & Paper (incl. Printing)
  • Other industries
  • Life Science

Product Family

  • Deltabar

Continuous / Liquids

Characteristic / Application

  • Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

Supply / Communication

  • 4...20 mA HART

Accuracy

  • 0.075% of individual sensor,
  • "PLATINUM" 0.05% of individual sensor

Long term stability

  • 0.05% of URL/year of individual sensor

Ambient temperature

  • –40...+80°C
  • (–40... +176°F)

Process temperature

  • –40...+125°C
  • (–40 ... +257°F)

Process pressure / max. overpressure limit

  • 160 bar (2400 psi)

Pressure measuring range

  • 400 mbar...10 bar
  • (6 psi...150 psi)

Main wetted parts

  • 316L, Alloy C

Process connection

  • Threads
  • Flange (DIN, ASME,JIS)

Process connection hygienic

  • DIN11851
  • DIN11864-1
  • Tri-Clamp
  • DRD
  • Varivent

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, FM, CSA, CSA C/US IEC Ex, NEPSI, INMETRO

Design approvals

  • NACE MR0175
  • EN10204-3.1

Hygienic approvals

  • FDA

Options

  • 4-line digital display
  • SS- or Aluminium housing

Application limits

  • Use the Software Applicator Sizing Electronic DP

Pressure

Characteristic

  • Electronic differential pressure transmitter with metal sensor for level, volume or mass measurement in liquids.

Supply voltage

  • 4...20 mA HART:
  • 12...45V DC (Non Ex)
  • Ex ia: 12...30V DC

Reference Accuracy

  • 0.075% of individual sensor,
  • "PLATINUM" 0.05% of individual sensor

Long term stability

  • 0.05% of URL/year of individual sensor

Process temperature

  • –40...+125°C
  • (–40...+257°F)

Ambient temperature

  • –40...+80°C
  • (–40...+176°F)

Measuring cell

  • 400 mbar...10 bar
  • (6 psi...150psi)

Vacuum resistance

  • 10 mbar (0.15 psi)

Max. overpressure limit

  • 160 bar (2400 psi)

Process connection

  • Threads
  • Flange (DIN, ASME,JIS)

Process connection hygienic

  • DIN11851
  • DIN11864-1
  • Tri-Clamp
  • DRD
  • Varivent

Material process membrane

  • 316L, AlloyC,

Fill fluid

  • Silicone oil
  • Synthetic oil

Material housing

  • Die-cast aluminum
  • Stainless steel

Communication

  • 4...20 mA HART

Certificates / Approvals

  • ATEX, FM, CSA, IECEx, NEPSI, INMETRO, UK Ex

Design approvals

  • NACE MR0175,
  • EN10204-3.1,

Hygienic approvals

  • EHEDG
  • 3A
show more