Electromagnetic flowmeter Promag 55S
Brand: Endress+HauserElectromagnetic flowmeter Promag 55S
Brand: Endress+Hauser
Xpert Specs at a Glance
Wetted materials:
Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum
Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum
Max. measurement error:
Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Max. process pressure:
PN 40, Cl. 300, JIS 20 K
Measuring range:
0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Medium temperature range:
0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
Field of application
Electromagnetic flowmeter
Specifications
Brand
Industry
- Water, Wastewater & Waste
- Food & Beverage
- Mining, Minerals & Metals
Product Family
- Promag
Liquids
Product headline
- The flowmeter with outstanding abrasion resistance and integrated solids content diagnostics.
- Superb signal stability due to unique signal processing.
- Ideal for the most demanding applications with high solids content and high abrasion.
Sensor features
- Maximum safety – industry-optimized measuring electrodes and linings. Energy‐saving flow measurement – no pressure loss due to cross section constriction. Maintenance‐free – no moving parts.
- Intensified coil system. Large range of liners. Solids content up to 80 % by weight.
Transmitter features
- Highest performance – with integrated solids measurement for demanding fluids. Highest safety – integrated electrode cleaning. Automatic recovery of data for servicing.
- 4-line backlit display with touch control. Two switch outputs. HART, PROFIBUS PA/DP, FOUNDATION Fieldbus.
Nominal diameter range
- DN 15...600
- 1/2"...24"
Wetted materials
- Liner: Polyurethane, Hard rubber, PFA, PTFE, Natural rubber
- Electrodes: 1.4435/304L, Alloy C-22, Tantalum, Platinum, Duplex 1.4465, Tungsten carbide, Titanum
Measured variables
- Volume flow, electrical conductivity, mass flow
Max. measurement error
- Volume flow: ±0.5 % o.r.± 1 mm/s (0.04 in/s)
- Option: ±0.2 % o.r. ± 2 mm/s (0.08 in/s)
Measuring range
- 0.06 dm3/min to 600 m3/h (0.015 gal/min to 2650 gal/min)
Max. process pressure
- PN 40, Cl. 300, JIS 20 K
Medium temperature range
- 0 to +60 °C (+32 to +140 °F), 0 to +80 °C (+32 to +176 °F), –20 to +50 °C (–4 to +122 °F), –20 to +180 °C (–4 to +356 °F), –20 to +150 °C (–4 to +266 °F)
Ambient temperature range
- –40 to +60 °C (–40 to +140 °F)
Sensor housing material
- Aluminum coated AlSi10Mg, carbon steel with protective varnish
Transmitter housing material
- Powder-coated die-cast aluminum
Degree of protection
- Standard: IP 67 (Type 4X enclosure) for transmitter and sensor
- Optional: IP 68 (Type 6P enclosure) for remote version of Promag S sensor
Display/Operation
- Liquid-crystal display: illuminated, four lines with 16 characters per line
- Onsite operation with three optical sensor keys
Outputs
- 4...20mA
- (active/passive) Pulse-/ Frequency output (active/passive)
- Two status outputs
Inputs
- Status
- Current input
Digital communication
- HART, PROFIBUS DP/PA, FOUNDATION Fieldbus
Power supply
- AC 20 to 260 V
- DC 20 to 64 V
Hazardous area approvals
- ATEX, FM, CSA, UK Ex
Product safety
- CE, C-tick, EAC marking
Pressure approvals and certificates
- CRN, PED
Material certificates
- 3.1 material
Hygienic approvals and certificates
- Drinking water approval:ACS, KTW/W270, NSF 61, WRAS BS 6920
Documentation
BA (Operating instruction)
- Proline Promag 55 pdf
- Proline Promag 55 pdf
- Proline Promag 55
FOUNDATION Fieldbus
Description of
Device Functions pdf - Proline Promag 55
FOUNDATION Fieldbus
Operating Instructions pdf - Proline Promag 55
PROFIBUS DP/PA
Description of Device Functions pdf - Proline Promag 55
PROFIBUS DP/PA
Operating Instructions pdf